12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu

Product Details
Customization: Available
Task: Adjust
Structure: Combination
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Patents Awarded
The supplier had awarded 3 patents, you can check the Audit Report for more information
to see all verified strength labels (23)
  • 12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu
  • 12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu
  • 12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu
  • 12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu
  • 12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu
  • 12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu
Find Similar Products

Basic Info.

Model NO.
22
Signal
Continuous
Function
Automatic Control, Protection, Monitoring, Measurement
Certification
ISO: 9001, CE
Condition
Used
Customized
Customized
Material
Stainless Steel
Features
Full Sealed&Insulation, Metalclad Withdrawable
Application Range
Power Plants
Transport Package
Standard Export Shipping Package
Specification
customized
Trademark
Insulation Electrica
Origin
China

Product Description

12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu
General Information

The 12kV SF6 gas insulated metal fully enclosed and fully insulated series ring network switch cabinets produced by the company are widely used in 12kV power distribution systems and are the preferred switch products for power transformation and distribution systems for various urban and rural users.

The switch cabinet is a modular unit model that can be combined according to different uses; it is divided into two categories: fixed unit combinations and expandable units to meet the needs of various substations for flexible use of compact switch cabinets.

The 12kV GIS switch cabinet is a completely sealed system, with its electrical components and switches enclosed in a stainless steel body. The entire switchgear is not affected by external environmental conditions, thus ensuring operational reliability and personal safety. And it is maintenance-free. By choosing expandable busbars, any combination can be achieved, achieving full modularity. Extended busbar safety insulation and shielding ensure reliability and safety.

The 12kV GIS switch cabinet can also provide TV-based automation solutions, forming the concept of intelligent switches and minimizing the workload of on-site installation and debugging.

12kV GIS switchgear is divided into non-extended standard configuration and expandable standard configuration. Due to its full-module and semi-module combination and self-expandability, it has extremely special flexibility.

The design life is over 30 years operating under indoor conditions (20C).

Functions and Features

1. Operation Safety.
a. Through the following safety measures, we can provide users with special safety guarantees: integrated three-station load switch.
b. The circuit breaker uses a load switch instead of an isolation switch, which is safer and more reliable. Fully sealed design on one side.
c. Mechanical interlocking that meets the five-proof requirements.
d. The live indicator can provide live indication of the incoming and outgoing lines.
e. The switch cabinet can be equipped with electric, remote control and monitoring devices to simulate the different needs of users.
f. The switch cabinet has a reliable safety pressure relief channel, which can ensure the personal safety of operators even in extreme circumstances.

 

  1. Reliable Operation.
  2. 12kVGIScabinet uses SF6 gas as arc extinguishing and insulating medium.
  3. The switch cabinet is a fully sealed and fully insulated structure. Busbars, switches and live parts are completely enclosed in a stainless steel housing. The chamber is inflated with 1.4bar SF6 gas, and the protection level reaches IP67. The entire switch device is completely unaffected by external environmental conditions, such as dust, moisture, small animals, etc. It can ensure normal operation of the switch even in extreme situations such as short-term water immersion, and the product is maintenance-free for life.
  4. The spring energy storage operating mechanism can provide manual or electric operation panel simulation line diagram to provide switch position indication.
  5. The cabinet is made of galvanized sheet, and the surface is electrostatically sprayed to enhance corrosion resistance. The pressure gauge monitors the safe pressure range of SF6 gas in the cabinet.

 

  1. Flexible Plan.

A variety of wire entry methods can realize various combinations of left, right, upper or forward wires. Any combination between units can be achieved using insulated bus bars, which can realize flexible design solutions of front and rear cabinets or left and right cabinets.

 

  1. Widely Used.
  2. Switch cabinets are divided into fixed unit combinations and expandable unit combinations.
  3. The switch cabinet usually enters and exits the wires from the front, and can also achieve side wires or side expansion according to different installation positions.
  4. The cabinet size is convenient for installation and can be suitable for places with small spaces and poor environmental conditions.

12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu

Switchgear Structure

12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu

  1. . Fuse room.
  2. . Capacitive voltage indicator.
  3. (). Short circuit to ground fault indicator (accessory).
  4. . Pressure indicator.
  5. . Standard with serial number.
  6. . Analog circuit diagram.
  7. . Blown fuse indicator.
  8. . Padlock mechanism on panel.
  9. . Cable chamber.
  10. RTU. RTU installation room.
  11. (). Key lock (accessory).
  12. . Circuit breaker operating hole.
  13. . Load switch operating hole.
  14. . Grounding switch operation hole.
  15. . Isolating switch operating hole.
  16. . Opening button.
  17. . Closing button.

Design Notes

  1. Technical Description.

The 12kV series GIS switch cabinet is installed on a galvanized sheet frame, and the switch unit is in an SF6 air box. The air box is made of corrosion-resistant and non-magnetic 3mm thick stainless steel plate.

The SF6 air box is a "sealed pressure system" that can operate for 20 years under normal working conditions. The pressure of SF6 gas during normal operation is 0.15~0.4bar. The air box is equipped with a pressure release device to ensure that the gas can be released from the bottom or rear when the pressure is too high.

  1. Switch Unit.

The load switch adopts a coaxial rotating double breakpoint method, and cooperates with the sliding plate through the same operating hole for kinetic operation. Therefore, the switch can only be in one of the three states of "closing, opening, and grounding" at any time, completely avoiding errors. operate.

  1. Operating Mechanism.

The operating mechanism of the switch is installed on the front outside the air box. It is treated with special technology to prevent corrosion, facilitate manual operation and maintenance, and can easily realize electric operation.

Usage Environment and Conditions

  1. The ambient air temperature does not exceed 40ºC, and the average value measured within 24 hours does not exceed 35ºC, and the minimum ambient air temperature is -40ºC;

Altitude ≤2000m.

  1. Humidity: Relative humidity: the daily average does not exceed 95%, and the monthly average does not exceed 90%.
  2. Water vapor pressure: the daily average value does not exceed 2.2KPA, and the monthly average value does not exceed 1.8KPA.
  3. Earthquake intensity: no more than 8 degrees, horizontal acceleration ≤ 0.4g, vertical acceleration ≤ 0.2g.
  4. Special conditions of use: When the actual use conditions exceed the normal use conditions, the user and the manufacturer shall negotiate.

Installation Dimension Drawing

 

Foundation Diagram

12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu

Standard Unit.

12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu

12kV Metering Cabinet or PT Cabinet.

12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu

GIS Switchgear Operating Mechanism

The operating mechanism room is located in the upper part of the GIS cabinet. The mechanism rollers are closely matched with the switch operating panel. The bolt fixing mechanism is divided into single spring (incoming line mechanism) and double spring (outgoing line mechanism) to form the ring network loop and transformer loop respectively. The switches and springs are all disc springs, which have the characteristics of high assembly precision, small operating force, long life and high stability.

12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu

Product Schematic Diagram

12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu

Switchgear Enclosures

Auxiliary Contact: All load switches and circuit breakers can be equipped with 2NO+2NC indicating switch position. A parallel release coil (AC or DC) can be installed on a transformer switch/circuit breaker. The low voltage control unit is located behind the front panel.

Voltage Indication: Capacitive voltage indicator shows whether the bushing is charged and the socket on it can be used for phase checking.

Short Circuit/Grounding Fault Indicator: In order to facilitate fault location, the cable switch module can be equipped with short circuit/ground fault indicator for simple fault detection.

Electric Operation: Manual operation mechanism of cable switching unit and transformer unit is a standard scheme. Electric operation mechanism can also be installed.Cable switches, vacuum circuit breakers and grounding switches are operated by a mechanism located behind the front panel. For all switches and circuit breakers, they can be operated by operating handles (standard configuration), or can be equipped with motor operating mechanisms (accessories). However, the grounding switch can only be operated manually and is equipped with a mechanism capable of closing the fault current. Electric operation mechanism can be easily implemented in stages.

 

Cable Connection: Our gas insulated cabinet is equipped with standard bushing. All bushings are of the same height from the ground and are protected by cable chamber covers. The cover plate can be interlocked with the grounding switch, and special double cable chamber cover plate can also be used for double cable access.

 

Pressure Indicator: Usually equipped with pressure indicator, which is in the form of pressure gauge. In addition, electrical contacts can be equipped to indicate pressure reduction.

Arc Extinguishing Device: Arc extinguishers can be installed in all 12kV GIS ring network units. When the internal arcing occurs, the arc extinguisher automatically closes on the incoming bushing. The 12kV GIS switch and all cable modules of 12kV GIS switchgear including De, De and V modules can be equipped with an arc extinguisher. They must order with the unit without changing it.

The action of the arc extinguisher can indicate the SF6 in the cabinet in this way. The electrical contacts in the cabinet are wired to terminal blocks behind the front panel.

12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu

External Busbar: switchgear can be equipped with external busbar.

12kv-630A Sf6 Gas Insulated Switchgear Gis Rmu

Base: Gas insulated switchgear can be installed on a separate base. The design of the base has reserved cable entrance at both ends and behind. Two different heights are 272 mm and450 mm respectively.

 

Secondary line chamber/low pressure chamber: switchgear can be equipped with secondary cabinet or low voltage box on the top of the switchgear. The secondary cabinet is used to install ammeter (with or without switch) and live locking control unit. The low-voltage box is used to install relays such as SPAJ140 C, ammeter (with or without switch) and live locking control unit.

 

Lightning Arrester: Zinc oxide arrester can be installed in the cable of our switchgear cabinet, and zinc oxide arrester can also be installed in the bus or MP cabinet of our switch cabinet.

 

Special Customization

The above parameters are typical data; if the existing styles do not meet your specific demands, please contact us for a custom design.We have significant personalized customization development and production skills, allowing us to provide tailored solutions to customers all over the world.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier