  • Kyn550-12kv Metal Clad Withdrawable Switchgear
  • Kyn550-12kv Metal Clad Withdrawable Switchgear
  • Kyn550-12kv Metal Clad Withdrawable Switchgear
  • Kyn550-12kv Metal Clad Withdrawable Switchgear
  • Kyn550-12kv Metal Clad Withdrawable Switchgear
  • Kyn550-12kv Metal Clad Withdrawable Switchgear
Find Similar Products

Basic Info.

Model NO.
23
Mathematical Model
Linear
Signal
Continuous
Function
Automatic Control, Protection, Monitoring, Measurement
Certification
ISO: 9001, CE
Condition
Used
Customized
Customized
Material
Stainless Steel
Features
Full Sealed&Insulation, Metalclad Withdrawable
Application Range
Power Plants
Transport Package
Standard Export Shipping Package
Specification
customized
Trademark
Insulation Electrica
Origin
China
HS Code
3707

Product Description

Kyn550-12kv Metal Clad Withdrawable Switchgear
Main 
Highlights

  1. The circular main busbar has many advantages such as high mechanical strength, uniform electric field distribution, and resistance as low as 15-20uΩ.
  2. The modular vacuum circuit breaker is an integrated F-type design with excellent insulation performance, few parts, a mechanical life of 30,000 times, and excellent performance.
  3. The U-shaped integrated design of the withdrawable modular current transformer has a large creepage distance and the power frequency withstand voltage can reach 4.5kV (to ground).
  4. The pull-out modular grounding switch has a simple structure, labor-saving operation and convenient installation.
  5. Full life cycle management Full life cycle management, product materials can be recycled, green and low carbon.

Kyn550-12kv Metal Clad Withdrawable Switchgear

Design principles

 

Humanized Design

  1. Rotary opening door lock enables easy door opening and strong locking.
  2. The handle door lock design is more convenient, more beautiful and safer.
  3. All panel components are arranged in accordance with ergonomic principles, and all operating instructions have humanized prompts.
  4. The switch cabinet adopts the principle of natural ventilation, and the size and height of the inlet and outlet vents are carefully designed to ensure that the temperature rise inside the switch cabinet is within a controllable range.
  5. Open the back door of the switch cabinet and cables can be installed.
  6. Conventional cable heads can be used, suitable for connecting multiple cables of various common specifications.
  7. The panel sets up the main circuit dynamic simulation and visualizes the position status of various components.
  8. The on-site installation and cabinet assembly process is simple and requires no special tools. The system can be expanded on both sides and can also be expanded and spliced with the KYN28 cabinet series.
  9. Full life cycle management, zero emission, no pollution, green and environmentally friendly, with a service life of up to 25 years.

Intelligent Design

The intelligent control of KYN550-12 armored metal-enclosed switchgear can realize online detection and fault diagnosis of its equipment including circuit breakers and contacts.

It can also provide fault alarms and automatically switch on and off auxiliary equipment such as fans and heaters. It also has the function of microcomputer remote communication, which can remotely realize the opening and closing of high-voltage circuit breaker, switching between working position and test position, opening and closing operation of grounding switch, etc. It has intelligent touch control, real-time data online display, and risk warning.

Kyn550-12kv Metal Clad Withdrawable Switchgear

Safety Performance Design

  1. Metal armor and fully enclosed structure can prevent dirt and small animals from entering.
  2. The cabinet adopts high-strength riveting technology, and the high-strength standard parts used in the installation of each component are all 10.9-level semi-circular heads to avoid tip discharge.
  3. It adopts composite insulation structure, which has better heat resistance, insulation and corrosion resistance. The continuous power supply is reliable and ensures the operation of the equipment.
  4. Mandatory closing operation to ensure the personal safety of operators.
  5. Reliable and comprehensive interlocking device effectively prevents misoperation.
  6. The quick-closing grounding switch is used for grounding on the cable side to facilitate maintenance and inspection.
  7. Small size and light weight. Approximate weight of cabinet: KYN28/458Kg>KYN550/420Kg, weight of circuit breaker: KYN28/135Kg>KYN550/95Kg.
  8. The creepage distance is larger and the safety performance is better. Creepage distance: KYN28/180mm<KYN550/240mm. Insulation method: KYN28/air<KYN550/composite insulation.
  9. Long service life and better performance. The circuit resistance of the whole cabinet: KYN28/≤150uΩ>KYN550/≤95uΩ, the service life of the equipment: KYN28/20 years <KYN550/25 years.
  10. Widely applicable environment. Low temperature environment: KYN28/-15ºC<KYN550/-35ºC.

Kyn550-12kv Metal Clad Withdrawable SwitchgearKyn550-12kv Metal Clad Withdrawable Switchgear

Use Conditional Environment

  1. Air temperature: minimum temperature -15ºC, maximum temperature +40ºC, 24-hour average temperature +35ºC.
  2. Altitude: 2000m.
  3. Humidity (relative humidity), daily average ≤95%, monthly average ≤90%.

Installation and Commissioning

The installation foundation construction of switch cabinets should comply with the relevant provisions of the "Technical Specifications for Electric Power Construction and Acceptance". The installation foundation of the switch cabinet generally requires secondary pouring of concrete. The first time is the installation basis of the switch cabinet installation components, that is, angle steel, square steel or channel steel components. When pouring concrete for the second time, the supplementary layer on the ground is generally 60mm thick. When pouring the supplementary concrete layer, the height of the concrete should be 1~3mm lower than the component plane. During civil construction, the foundation elevation of the switch cabinet should consider reserving the height of the channel steel of the foundation cabinet, with a slight margin, and pre-embed steel plates on the switch cabinet at intervals of 1 to 1.5 meters along the longitudinal direction of the frame.

When installing the basic structure, the installation quality must be ensured. The technical standard for structure installation is a tolerance of 1mm per square meter. The basic frame is composed of welded channel steel and angle steel. The basic size requirements of the frame and the cable channel layout are shown in the attached drawing. The extension distance of the channel steel of the basic frame should be consistent with the size of the switch cabinet body frame. When the cabinets are arranged in a single row, the corridor in front of the cabinet is preferably 2.5 meters; when the cabinets are arranged in double rows, the operating corridor between the cabinets is preferably 3 meters.

During the transportation of switch cabinets, specific means of transportation should be used, such as cranes or forklifts. It is strictly forbidden to use roller crowbars, and it is strictly forbidden to push the circuit breaker handcart into the cabinet and transport it together. The circuit breaker handcart (and other handcarts) can only be pushed into the corresponding small room after the cabinet is installed.

Kyn550-12kv Metal Clad Withdrawable Switchgear

Construction Foundation Drawing

Kyn550-12kv Metal Clad Withdrawable SwitchgearKyn550-12kv Metal Clad Withdrawable Switchgear

Special Customization

The above parameters are typical data; if the existing styles do not meet your specific demands, please contact us for a custom design.We have significant personalized customization development and production skills, allowing us to provide tailored solutions to customers all over the world.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier